CSTrueBeauty
Fractional Amazing RF Facial Beauty Equipment Wrinkle Remove RF Skin Tightening Beauty Machine
Fractional Amazing RF Facial Beauty Equipment Wrinkle Remove RF Skin Tightening Beauty Machine
Couldn't load pickup availability
Cstruebeauty MF-268 6-in-1 RF EMS Facial & Body Beauty Machine
Professional 4MHz Radiofrequency and EMS System with Six Applicators, Vacuum Technology & Cooling
6 Specialized Handpieces | 4MHz RF | 200Hz EMS | 90kPa Listed Vacuum | 12.1-Inch Touchscreen
The Cstruebeauty MF-268 6-in-1 RF EMS Facial & Body Beauty Machine is a professional aesthetic equipment platform combining radiofrequency, electrical muscle stimulation, vacuum-related body care functions, and cooling technology.
Designed for beauty salons, facial studios, spas, and professional beauty equipment buyers, the MF-268 includes six specialized handpieces:
-
One eye-area RF applicator
-
Two facial RF applicators
-
Two body RF applicators
-
One cooling applicator
The system features a 12.1-inch capacitive touchscreen and separate operating interfaces for facial and body equipment functions.
With manufacturer-listed 4MHz RF technology, 200Hz EMS, and a vacuum specification of 90kPa, the MF-268 offers a multifunctional equipment configuration for professional cosmetic care.
Six Specialized Applicators
1. Eye-Area RF Applicator
Compact Radiofrequency Head for Selected Facial Areas
The eye-area RF applicator features a smaller contact design intended for the manufacturer's eye-contour skincare category.
Its compact shape distinguishes it from the larger facial and body applicators.
The device's suitability near the eyes must be verified from the manufacturer's safety instructions. Direct application to the eyes or eyelids must not be assumed safe.
2. Rectangular Facial RF Applicator
Dedicated Facial Radiofrequency Configuration
The rectangular facial applicator features a flat contact arrangement designed for the manufacturer's facial RF operating category.
It provides a separate head shape for professional cosmetic facial care workflows.
3. Circular Facial RF Applicator
Multi-Ring Contact Head
The circular facial handpiece features a ring-shaped electrode design.
Its physical contact arrangement provides an alternative configuration to the rectangular facial applicator.
Key characteristics:
-
Circular RF contact surface
-
Dedicated facial handpiece
-
Integrated equipment connection
-
Touchscreen-based control system
4. Rectangular Body RF Applicator
Body Care with Manufacturer-Described Vacuum Technology
The rectangular body handpiece is shown in the supplier's vacuum-assisted body-care equipment category.
The manufacturer describes a combination of negative pressure and radiofrequency in the body applicator system.
This configuration is positioned for selected cosmetic services involving the abdomen, arms, thighs, and other manufacturer-designated body areas.
Actual suction operation and the energy capabilities of this particular handpiece should be confirmed before selecting treatment settings.
5. Circular Body RF Applicator
Large-Format Radiofrequency Body Head
The circular body applicator incorporates a larger ring-shaped contact surface.
It provides a separate body RF handpiece configuration for the manufacturer's body contouring and skin-appearance equipment category.
The device's actual RF output parameters and authorized application areas must be confirmed.
6. Ice Hammer Cooling Applicator
Contact Cooling for Professional Facial Care
The MF-268 includes one dedicated cooling handpiece.
The manufacturer lists an operating temperature of 0–10°C.
This applicator provides a separate temperature-based contact-care function within the equipment platform.
Cooling settings must be used according to the device's safety instructions.
Core Technologies
4MHz Radiofrequency
The MF-268 features manufacturer-listed 4MHz RF technology.
Radiofrequency energy can produce heating effects in tissue, depending on the applicator design and output settings.
The system includes several RF applicator shapes for different cosmetic equipment workflows.
200Hz Electrical Muscle Stimulation
The manufacturer specifies the following EMS parameters:
-
EMS frequency: 200Hz
-
EMS pulse width: 200μs
Electrical muscle stimulation applies electrical impulses that may cause muscle activation, depending on the device's electrode design and operating conditions.
The exact distribution of EMS functionality across the six handpieces should be confirmed from the model-specific operating instructions.
Vacuum-Assisted Body Equipment
The supplier lists a 90kPa vacuum specification and describes negative-pressure functionality in its body applicator system.
Vacuum technology is a separate physical mechanism from RF heating and electrical stimulation.
The available suction controls, operating range, and which applicators support vacuum require confirmation.
Integrated Cooling Function
The system provides a dedicated cold-contact applicator with a manufacturer-listed 0–10°C temperature specification.
Its separate cooling design allows qualified operators to incorporate temperature-based care into appropriate cosmetic workflows.
12.1-Inch Capacitive Touchscreen
The MF-268 features a large 12.1-inch capacitive display.
The manufacturer's illustrated interface includes:
-
Face and body function selection
-
RF control settings
-
EMS control settings
-
Adjustable treatment parameters
-
Session operation controls
-
Equipment settings
Available Equipment Colors
The manufacturer illustrates three color configurations:
-
Orange White
-
Black
-
Silver Gray
Color availability should be confirmed when placing an order.
Technical Specifications
| Specification | Details |
|---|---|
| Brand | Cstruebeauty |
| Reference Model | MF-268 |
| Product Category | Multifunctional RF EMS Beauty Equipment |
| Main Technologies | Radiofrequency, EMS, Vacuum, Cooling |
| Handpiece Quantity | 6 |
| Facial Handpieces | 3 |
| Body Handpieces | 2 |
| Cooling Handpiece | 1 |
| RF Frequency | 4MHz |
| EMS Frequency | 200Hz |
| EMS Pulse Width | 200μs |
| Vacuum Specification | 90kPa, Manufacturer-Listed |
| Ice Hammer Temperature | 0–10°C |
| Rated Equipment Power | 300W |
| Display | 12.1-Inch Capacitive Touchscreen |
| Electrical Supply | 110V / 220V, 50/60Hz |
| Fuse Specification | 10A / 15A |
| Net Weight | 15kg |
| Gross Weight | 35kg |
| Packing Dimensions | 110 × 54 × 48cm |
| Available Colors | Orange White, Black, Silver Gray |
| RF Output Power | Not Specified |
| Independent EMS Output Current | Not Specified |
These specifications are based on the supplied manufacturer brochure. Final electrical versions, operating functions, and handpiece configurations should be confirmed before ordering.
Documented Equipment Configuration
The manufacturer's accessory illustrations identify:
-
1 × MF-268 main console
-
1 × Eye-area RF applicator
-
2 × Facial RF applicators
-
2 × Body RF applicators
-
1 × Ice Hammer cooling applicator
-
1 × Integrated touchscreen control system
-
Built-in applicator holders
-
Manufacturer-illustrated vacuum collection bottle
The complete commercial packing list, power accessories, and replacement parts should be confirmed before shipment.
Why Choose the Cstruebeauty MF-268?
Six Specialized Applicators
Distinct equipment-head designs for face, body, and contact cooling.
4MHz Radiofrequency Platform
A clearly listed nominal RF frequency.
Integrated EMS Technology
Manufacturer-specified 200Hz EMS frequency and 200μs pulse width.
Vacuum-Related Body Care
Negative-pressure equipment functionality within the body applicator platform.
Dedicated Cooling Handpiece
A separate cold-contact applicator with a manufacturer-listed temperature specification.
12.1-Inch Touchscreen
Large digital interface for equipment operation.
Professional Equipment Design
A wheeled console with applicator storage and several advertised color options.
Frequently Asked Questions
What is the Cstruebeauty MF-268?
The MF-268 is a professional multifunctional beauty machine combining radiofrequency, electrical muscle stimulation, manufacturer-described vacuum functionality, and cooling.
How many handpieces does it include?
Six: three facial RF applicators, two body RF applicators, and one Ice Hammer.
What is the RF frequency?
The manufacturer specifies 4MHz.
What are the EMS specifications?
The manufacturer lists a 200Hz frequency and 200μs pulse width.
Does the machine include vacuum technology?
Yes. The supplier describes vacuum-related functionality and lists a 90kPa specification. The exact suction range and handpiece allocation require confirmation.
What temperature does the Ice Hammer use?
The manufacturer's listed temperature specification is 0–10°C.
What screen size does the machine have?
A 12.1-inch capacitive touchscreen.
Does every handpiece include RF and EMS?
The brochure does not establish that every handpiece provides both functions. The actual available outputs depend on the applicator configuration.
Is this equipment intended for facial and body services?
The manufacturer illustrates dedicated facial and body applicators. Actual permitted uses must follow the device's verified instructions.
Does the machine guarantee wrinkle removal or fat reduction?
No particular cosmetic outcome can be guaranteed from the supplied brochure. Performance depends on equipment characteristics and appropriate supporting evidence.
Request Wholesale Equipment Information
Explore the Cstruebeauty MF-268 6-in-1 RF EMS Facial & Body Beauty Machine with six specialized applicators, 4MHz RF, 200Hz EMS, vacuum-related body functions, cooling, and a 12.1-inch touchscreen.
Contact Cstruebeauty to request:
-
Complete technical specifications
-
Detailed applicator operating functions
-
Confirmed RF and EMS output characteristics
-
Vacuum control and cooling information
-
Available color configurations
-
Replacement parts and maintenance details
-
Professional wholesale pricing
-
International shipping information
Contact Cstruebeauty for a detailed equipment quotation.
Important Safety Information
The MF-268 combines energy-based skincare technologies and may cause burns, irritation, bruising, electrical discomfort, or cold-related skin injury if used incorrectly.
Professionals must follow the manufacturer's operating instructions, assess individual suitability, and observe appropriate safety precautions.
Special care is required when using applicators near the eyes. Electrical stimulation and RF functions may be unsuitable for individuals with implanted electronic devices or other relevant contraindications.
This description does not guarantee painless procedures, permanent fat loss, wrinkle elimination, or specific treatment results.
Share