CSTrueBeauty
Cstruebeauty F37+RF Professional 4-Applicator HIFEM & Monopolar RF Body Contouring Machine — 7 Tesla, 40.68MHz RF, Dual RF Channels & Touchscreen
Cstruebeauty F37+RF Professional 4-Applicator HIFEM & Monopolar RF Body Contouring Machine — 7 Tesla, 40.68MHz RF, Dual RF Channels & Touchscreen
Couldn't load pickup availability
Cstruebeauty F37+RF 4-Applicator HIFEM & Monopolar RF Body Contouring Machine
Professional High-Intensity Electromagnetic Muscle Stimulation System with Dual 40.68MHz RF Channels, 7 Tesla Manufacturer-Listed Magnetic Field & Touchscreen Control
4 Magnetic Applicators | 2 Independent RF Channels | 40.68MHz Monopolar RF | 3–150Hz Magnetic Stimulation | Auto & Manual Modes
The Cstruebeauty F37+RF 4-Applicator HIFEM & Monopolar RF Body Contouring Machine combines high-intensity electromagnetic muscle stimulation with radiofrequency technology in a professional tabletop platform.
Featuring four magnetic applicators, two independently controlled RF channels, adjustable magnetic stimulation frequencies and multiple software programs, the F37+RF provides a flexible equipment configuration for professional body-contouring facilities and aesthetic equipment distributors.
The manufacturer lists a magnetic-field rating of 7 Tesla, a monopolar RF frequency of 40.68MHz, and an output-power range of 300–4000W.
The system supports paired or four-applicator magnetic operation, with RF controls assigned specifically to applicators A and B.
Its digital touchscreen includes automatic and manual operating modes, individual channel adjustments, programmable frequency settings and session-time controls.
Key Features & Technologies
1. High-Intensity Focused Electromagnetic Technology
The F37+RF uses manufacturer-described high-intensity focused electromagnetic technology to generate changing magnetic fields through specialized applicators.
These magnetic fields are intended to induce muscle contractions without the conventional surface-electrode arrangement of wired EMS equipment.
Key equipment features:
-
Four electromagnetic applicators
-
Manufacturer-listed 7 Tesla magnetic-field rating
-
Adjustable stimulation frequency from 3–150Hz
-
Selectable magnetic intensity
-
Paired and four-applicator operating configurations
-
Automatic and manual programs
-
Digital session control
The actual magnetic field distribution, measurement location, and field characteristics require product-specific testing.
2. Four Magnetic Applicators
The system features four working applicators identified as:
-
Applicator A
-
Applicator B
-
Applicator C
-
Applicator D
The manufacturer's documentation describes paired and four-applicator synchronous magnetic operation.
The software groups the controls into:
A+B Magnetic Channel Group
Controls magnetic stimulation intensity for applicators A and B.
C+D Magnetic Channel Group
Controls magnetic stimulation intensity for applicators C and D.
The system also provides separate RF controls for A and B.
The exact combinations supported for different users and body areas must follow verified operating instructions.
3. Dual Monopolar Radiofrequency Channels
40.68MHz RF | A-RF + B-RF
The F37+RF includes two manufacturer-described monopolar RF channels.
These are assigned to applicators A and B.
Documented features:
-
Two RF output channels
-
RF control for applicator A
-
RF control for applicator B
-
Independent RF intensity adjustment
-
Combined magnetic and RF operating capability
-
Temperature-related operating specifications
The manufacturer lists an RF frequency of 40.68MHz and a temperature parameter of 40–50°C.
The listed temperature range is an equipment specification, not proof of the actual temperature reached in skin or underlying tissue.
Applicators C and D are not documented as having independent RF output.
4. Combined Magnetic & RF Equipment Platform
The F37+RF integrates two distinct technologies:
Electromagnetic Stimulation
Alternating magnetic-field output through the four applicators.
Monopolar Radiofrequency
RF energy delivered through the supported A and B applicators, subject to direct skin-contact requirements.
The manufacturer's operating instructions allow adjustment of magnetic and RF settings through the central touchscreen.
RF must only be enabled in supported areas with verified, full applicator contact.
5. Manufacturer-Listed 7 Tesla Magnetic Field
The technical table lists 7 Tesla as the magnetic vibration intensity.
This is a supplier-provided specification.
The manual does not identify:
-
Magnetic-field measurement location
-
Peak versus continuous-field definition
-
Measurement equipment
-
Test conditions
-
Field strength at different tissue depths
The 7 Tesla figure should therefore be presented as a manufacturer-listed rating until supported by a device-specific test report.
6. Adjustable 3–150Hz Magnetic Frequency
The manufacturer's technical specifications identify a magnetic stimulation frequency range of 3–150Hz.
The manual operating interface provides three frequency parameters:
| Frequency Stage | Manufacturer-Listed Range |
|---|---|
| F1 | 3–150Hz |
| F2 | 3–150Hz |
| F3 | 3–150Hz |
The manual describes cyclic operation of these stages.
Available controls allow users to adjust the programmed stimulation rhythm within the manufacturer's listed range.
7. Five Automatic Operating Programs
The F37+RF includes five automatic software programs.
HIIT
A manufacturer-designated introductory training program.
Obesity
A preset category described in the manufacturer's original interface.
Slightly Fat
A manufacturer-designated initial training program.
Shaping
A preset category associated with advanced stimulation routines.
Lose Weight
A manufacturer-designated professional training category.
These are the original program names shown in the equipment software.
They refer to selectable stimulation patterns and should not be interpreted as guaranteed weight-loss outcomes.
8. Six-Stage Automatic Program Structure
The manufacturer's automatic programming describes a six-stage sequence:
-
Warm-Up
-
Progressive Exercise
-
Muscle Activation
-
Strengthening
-
High-Intensity Stimulation
-
Relaxation
These represent sequential stimulation stages within the supplier's software concept.
The timing and actual pulse characteristics depend on the selected program.
9. Manual Frequency Programming
Manual mode allows the operator to adjust F1, F2 and F3 frequency parameters.
The source instructions describe a cyclic sequence using:
-
F1 for 5 minutes
-
F2 for 1 minute
-
F3 for 5 minutes
The software also allows independent intensity settings for the two magnetic channel groups and two RF controls.
Actual operating settings should follow the verified instructions for the supplied production version.
10. Adjustable Magnetic Intensity
The manufacturer's interface describes a magnetic intensity-setting scale from 8% to 100%.
Available adjustments include:
-
A+B magnetic intensity
-
C+D magnetic intensity
-
A-RF intensity
-
B-RF intensity
These percentages are software control settings rather than independently verified percentages of peak magnetic-field output.
11. Adjustable Working Timer
The manufacturer specifies:
-
Default session timer: 30 minutes
-
Adjustable working timer: 5–60 minutes
-
Start and pause controls
The maximum timer setting does not establish a safe or recommended duration for every person or application.
12. Applicator Geometry & Fastening
The manufacturer illustrates flat and curved applicator designs.
The accessories also include straps intended to secure the working applicators in position.
Design features:
-
Flat contact-head configuration
-
Curved contact-head configuration
-
Flexible positioning using compatible straps
-
Four external applicator connections
-
Dedicated RF contact points on supported applicators
The manual describes curved applicator geometry for selected anatomical shapes.
However, full RF contact is required for the RF-equipped applicators.
13. RF Contact Safety Controls
The manufacturer's instructions emphasize that RF output requires adequate, direct contact with the skin.
The manual warns that insufficient contact can cause localized overheating and burns.
Important operating requirements include:
-
Do not operate RF through clothing.
-
Keep the RF contact points fully against the appropriate skin surface.
-
Verify correct applicator positioning before starting.
-
Do not enable RF on areas where adequate contact cannot be maintained.
-
Avoid unsupported anatomical locations.
-
Stop operation if abnormal heating or discomfort occurs.
The manufacturer recommends RF use primarily in areas where full contact is achievable, such as suitable abdominal and leg surfaces.
Other positioning examples shown in the manual may relate to magnetic-only operation rather than combined RF use.
14. Air-Cooled Professional Console
The manual identifies an air-cooling system and specifies ventilation requirements.
The equipment features:
-
Tabletop main console
-
Integrated touchscreen
-
Four applicator connections
-
Two independently controlled RF outputs
-
Air-cooling ventilation
-
Main power switch
-
Power cable connection
-
Applicator storage supports
The manufacturer recommends approximately 30cm of clearance around the console for heat dissipation.
Technical Specifications
| Specification | Manufacturer-Listed Details |
|---|---|
| Brand | Cstruebeauty |
| Reference Model | F37+RF |
| Product Category | Professional Electromagnetic & RF Body Contouring Equipment |
| Main Technologies | HIFEM + Monopolar RF |
| Magnetic Applicators | 4 |
| Magnetic Control Groups | A+B / C+D |
| RF Channels | 2 |
| RF-Enabled Applicators | A and B |
| Magnetic Field Rating | 7 Tesla, Manufacturer-Listed |
| Magnetic Stimulation Frequency | 3–150Hz |
| Monopolar RF Frequency | 40.68MHz, Manufacturer-Described |
| RF Temperature Parameter | 40–50°C |
| Listed Output Power | 300–4000W |
| Adjustable Magnetic Intensity | 8–100% |
| Operating Modes | Automatic / Manual |
| Automatic Program Categories | 5 |
| Automatic Stimulation Stages | 6 |
| Manual Frequency Parameters | F1 / F2 / F3 |
| Adjustable Timer | 5–60 Minutes |
| Default Timer | 30 Minutes |
| Input Voltage | AC110V / 230V |
| Fuse | 20A |
| Cooling | Air Cooling |
| Main Console Dimensions | 52 × 39 × 34cm |
| Main Console Weight | 39kg |
| Shipping Case Dimensions | 64 × 46 × 79cm |
| Shipping Case Weight | 15kg |
| Gross Shipping Weight | Approximately 54kg |
| Recommended Operating Temperature | 5–40°C |
| Recommended Relative Humidity | ≤80% |
Specifications are based on the supplied F37+RF manufacturer manual. Magnetic-field strength, RF temperature performance, output-power definitions and final included accessories should be confirmed for the production unit.
Documented Equipment Configuration
The manufacturer's illustrations identify:
-
1 × Main F37+RF console
-
4 × Magnetic stimulation applicators
-
RF capability on applicators A and B
-
Applicator fastening straps
-
Applicator storage brackets
-
Main power cable
-
Touchscreen control interface
The manual illustrates multiple strap sizes but does not provide a complete itemized commercial packing list.
Final quantities of straps, brackets, cables, and other accessories should be confirmed before ordering.
Why Consider the Cstruebeauty F37+RF?
Four Magnetic Applicators
A four-handle platform with paired and four-applicator magnetic operation.
Dual RF Outputs
Independent RF control for the A and B applicators.
40.68MHz Monopolar RF
A clearly identified manufacturer-described RF frequency.
7 Tesla Manufacturer-Listed Rating
A magnetic-field specification requiring confirmation of its measurement conditions.
3–150Hz Adjustable Magnetic Stimulation
Frequency selection through automatic and manual controls.
Five Automatic Programs
Multiple selectable software stimulation routines.
Manual F1–F3 Programming
Adjustable frequency stages for different programmed stimulation patterns.
Professional Tabletop Design
Integrated touchscreen, applicator storage and air-cooled housing.
Professional Business Applications
The F37+RF is intended for professional buyers evaluating multifunction electromagnetic and radiofrequency equipment, including:
-
Body contouring studios
-
Aesthetic equipment distributors
-
Professional beauty equipment businesses
-
Spas and wellness facilities
-
Beauty equipment training centers
-
Aesthetic equipment procurement teams
Actual use must follow verified product-specific operating instructions, appropriate screening procedures and professional safety requirements.
Frequently Asked Questions
What is the Cstruebeauty F37+RF?
The F37+RF is a professional electromagnetic muscle stimulation system with four magnetic applicators and two independently controlled monopolar RF channels.
How many applicators does the machine include?
Four electromagnetic applicators, identified as A, B, C and D.
Do all four applicators include RF?
No. The manufacturer's documentation identifies RF controls specifically for applicators A and B.
Can all four magnetic applicators operate together?
The manual describes synchronous four-applicator magnetic operation.
What is the RF frequency?
The manufacturer identifies 40.68MHz.
What is the magnetic-field rating?
The manufacturer lists 7 Tesla. A test report is needed to establish the measurement location and operating conditions.
What is the magnetic stimulation frequency range?
3–150Hz.
How many automatic programs are available?
Five.
Can the magnetic frequency be adjusted manually?
Yes. The manual provides F1, F2 and F3 frequency controls.
What is the adjustable working time?
5–60 minutes.
What is the listed output power?
The supplier specifies 300–4000W but does not fully define the individual operating conditions or per-applicator output.
Does the device support RF through clothing?
No. The manufacturer specifically states that RF must not operate through clothing.
Can RF be used on every body area shown in the magnetic applicator positioning diagram?
No. The manual warns against enabling RF where full contact cannot be maintained, particularly on curved surfaces.
What are the console dimensions?
52 × 39 × 34cm.
What is the listed gross shipping weight?
Approximately 54kg.
Does the machine guarantee a certain percentage of fat loss or muscle growth?
No. The manufacturer's promotional materials include numerical outcome claims, but the documentation does not establish guaranteed results for the exact equipment configuration.
Request Wholesale Pricing & Technical Details
Explore the Cstruebeauty F37+RF 4-Applicator HIFEM & Monopolar RF Body Contouring Machine, featuring four magnetic applicators, two RF channels, 40.68MHz RF technology, adjustable magnetic frequency and a digital touchscreen.
Contact Cstruebeauty for:
-
Complete technical specifications
-
Verified magnetic-field test results
-
Confirmed A/B/C/D applicator configurations
-
RF output and temperature-control specifications
-
Clarification of the 300–4000W rating
-
Complete standard packing list
-
Electrical configuration for your market
-
Maintenance and replacement accessories
-
Professional wholesale pricing
-
International shipping details
Contact Cstruebeauty for a detailed equipment quotation.
Important Safety Information
High-intensity electromagnetic and radiofrequency equipment can cause strong muscle contractions, discomfort, localized heating, burns, or other adverse effects if improperly operated.
The manufacturer identifies restrictions involving pregnancy, certain implanted electronic devices, metal implants, cardiovascular conditions, epilepsy, and other relevant health conditions.
RF must not be operated through clothing or on areas where the applicator cannot maintain complete and stable contact with the skin.
Do not position applicators near the head, neck, carotid arteries, or chest in violation of the manufacturer's restrictions.
The equipment must be operated according to validated device-specific instructions.
No claim is made that the F37+RF guarantees permanent fat destruction, a specific increase in muscle mass, treatment of medical conditions, painless operation, or risk-free results.
Share
