Skip to product information
1 of 7

CSTRUEBEAUTY

Cstruebeauty BG862 60W Fractional CO2 Laser Machine with 12.1-Inch Touchscreen

Cstruebeauty BG862 60W Fractional CO2 Laser Machine with 12.1-Inch Touchscreen

Regular price $4,300.00 USD
Regular price $7,000.00 USD Sale price $4,300.00 USD
Sale Sold out
Free shipping to the United States.
Color
Plugs Type
Quantity

Cstruebeauty BG862 60W Fractional CO2 Laser Machine

Professional 10600nm CO2 Laser System with 12.1-Inch Touchscreen, Seven Scanning Patterns & Six-Joint Articulated Arm

60W Adjustable Laser Output | 10.6μm CO2 Wavelength | Fractional Scanning | Ultra Pulse Functions | Specialized Applicator Options

The Cstruebeauty BG862 60W Fractional CO2 Laser Machine is a professional laser equipment platform featuring a sealed-off carbon dioxide laser source, fractional scanning technology, multiple pulse-output configurations, and a precision articulated optical delivery system.

With a manufacturer-listed adjustable laser output of 1–60W, a 12.1-inch capacitive touchscreen, seven geometric scanning patterns, and a six-joint articulated laser arm, this system provides a range of technical configurations for qualified professional laser facilities.

The product materials illustrate fractional and ultra-pulse laser heads, along with specialized gynecological applicator designs.

The intended applications, supplied accessories, and operating permissions for each configuration must be confirmed for the exact production model.

Key Features & Technologies

1. Professional 10600nm CO2 Laser Technology

The BG862 uses a sealed-off CO2 laser source operating at a nominal wavelength of 10.6μm (10600nm).

CO2 laser radiation interacts strongly with water-containing tissue and can produce ablative and thermal effects depending on the delivered optical energy and operating parameters.

Main technical features:

  • 10600nm CO2 laser wavelength

  • Sealed-off laser source

  • Adjustable 1–60W manufacturer-listed laser output

  • Fractional scanning capability

  • Multiple pulse-output modes

  • Articulated beam-delivery system

  • Digital touchscreen controls

Because the CO2 treatment beam is invisible, the system incorporates a separate visible aiming beam.

2. Seven Fractional Scanning Patterns

The fractional laser head provides patterned scanning through the digital control interface.

The manufacturer illustrates seven geometric options:

  • Point

  • Line

  • Rectangle

  • Triangle

  • Hexagon

  • Square

  • Round

The touchscreen also illustrates adjustable scan size, spacing, power, pulse width, and other available controls.

The actual scan dimensions and optical exposure limits must be verified in the complete technical instructions.

3. Fractional Laser Applicator

The fractional head incorporates a scanning assembly for patterned laser delivery.

The manufacturer positions this applicator within professional fractional laser skin-resurfacing equipment.

Equipment characteristics:

  • Dedicated fractional scanning head

  • Seven selectable scan shapes

  • Adjustable scan geometry

  • Touchscreen parameter selection

  • Articulated optical delivery

  • Visible red aiming reference

Specific procedures and expected results require supporting product-specific technical and clinical information.

4. Ultra Pulse Laser Applicator

The system includes an ultra-pulse-style laser head in the illustrated accessory configuration.

The manufacturer describes several operating modes:

Single Pulse

Individual pulse-output configuration.

Repeated Pulse

A repeated pulsed-output configuration.

Continuous Pulse

A continuous-output configuration as described in the manufacturer's interface.

Super Pulse

A manufacturer-designated pulsed-output setting.

These modes are equipment-control options and do not establish recommended settings for any procedure.

5. Specialized Gynecological Applicator Configurations

The manufacturer illustrates two principal gynecological applicator designs:

  • Vaginal Whitening Applicator

  • Vaginal Tightening Applicator

Additional promotional diagrams show a 360-degree mirror applicator, cervix applicator, and vulva applicator options.

These descriptions reflect the manufacturer's accessory names, not verified clinical outcomes.

The exact included components, optical output geometry, compatibility, cleaning and sterilization procedures, and authorized uses require separate confirmation.

The inclusion of an intracavitary applicator does not establish effectiveness for vaginal tightening, pigmentation changes, vaginal dryness, urinary incontinence, or other conditions.

6. Six-Joint Articulated Laser Arm

The BG862 features a spring-balanced articulated light-guiding arm with six joints.

The manufacturer describes this system as supporting flexible positioning of the laser delivery head.

Design highlights:

  • Six articulated joints

  • Spring-balanced mechanical structure

  • Optical beam transmission

  • Compatibility with documented terminal-head configurations

  • Adjustable positioning for qualified operators

The actual transmission efficiency and optical alignment tolerances require technical verification.

7. Adjustable Laser Output: 1–60W

The source specifications list an adjustable laser output range of 1–60W.

The equipment also lists:

  • Beam divergence: 4mrad

  • Focused spot diameter: less than 0.4mm

  • Pulse width: 0.1–10ms

  • Optional F=100mm focusing component

These specifications describe the manufacturer's optical configuration and should be confirmed for the delivered machine.

8. 650nm Red Aiming Beam

The laser system incorporates a 650nm red diode aiming laser with manufacturer-listed output of 2mW.

This visible beam provides an optical reference for positioning.

The aiming laser is separate from the primary 10600nm CO2 laser source.

9. 12.1-Inch Capacitive Touchscreen

The BG862 includes a 12.1-inch capacitive touchscreen.

The illustrated interface features separate operating categories for:

  • Fractional laser

  • Surgery / pulse laser

  • Vaginal Whitening

  • Vaginal Tightening

  • System settings

The availability of software menus should not be treated as confirmation that every accessory is included or that every advertised clinical application is authorized.

10. Internal Cooling System

The manufacturer describes an internal circulating cooling arrangement.

The rear equipment diagram illustrates:

  • Water inlet/outlet connections

  • Overflow connection

  • Cooling-related chassis components

The complete coolant specification and maintenance procedure should be confirmed before operation.

11. Professional Safety and Control Components

The illustrated console includes:

  • Key-operated power control

  • Foot-switch connection

  • Touchscreen operating interface

  • Optical arm assembly

  • Main power switch

  • Laser connection socket

The manufacturer's instructions, protective equipment requirements, and emergency shutdown arrangements must be verified before use.

Technical Specifications

Specification Manufacturer-Listed Details
Product Reference BG862
Equipment Category Professional Fractional CO2 Laser System
Laser Source Sealed-Off CO2 Laser
Main Wavelength 10.6μm / 10600nm
Adjustable Laser Output 1–60W
Input Apparent Power 450VA
Beam Divergence 4mrad
Focused Spot Diameter Less Than 0.4mm
Pulse Width 0.1–10ms
Aiming Laser 650nm Red Diode Laser
Listed Aiming Output 2mW
Beam Delivery Six-Joint Articulated Arm
Main Display 12.1-Inch Capacitive Touchscreen
Fractional Scan Patterns 7
Output Modes Single Pulse, Repeated Pulse, Continuous Pulse, Super Pulse
Cooling Internal Circulating Cooling
Working Temperature 5–40°C
Atmospheric Pressure 86–106kPa
Working Humidity Below 80%
Listed Preheating Time More Than 5 Minutes
Equipment Net Weight 39kg
Gross Weight 56kg
Main Unit Dimensions 116 × 58 × 47cm
Laser Arm Package Dimensions 75 × 31 × 14cm
Input Voltage Not Specified in Supplied Materials

Specifications are based on the BG862 manufacturer brochure. The final product configuration, electrical supply, optical performance, and specialized accessories must be confirmed before commercial publication.

Illustrated Applicator & Accessory Options

The supplier's product materials illustrate:

  • Fractional laser scanning head

  • Ultra Pulse laser head

  • Vaginal Whitening applicator

  • Vaginal Tightening applicator

  • Six-joint articulated laser arm

  • Foot-switch control

  • Main laser console

Additional specialty accessories may be available, but the brochure does not establish a complete standard commercial packing list.

Professional Equipment Applications

Fractional Laser Equipment

A scanning CO2 laser platform for facilities evaluating professional fractional laser hardware.

Professional Laser Procedures

Pulse and continuous-output configurations with interchangeable terminal applicator designs.

Aesthetic Equipment Procurement

A floor-standing laser console with a large touchscreen and articulated beam-delivery arm.

Specialized Gynecological Equipment

Manufacturer-illustrated specialty accessories requiring separate verification of permitted procedures, operator qualifications, and infection-control requirements.

All intended uses must be supported by the actual device's validated documentation.

Why Consider the Cstruebeauty BG862?

60W Listed Laser Output

Manufacturer-described adjustable power from 1W to 60W.

10600nm CO2 Technology

A clearly specified laser wavelength.

Seven Scan Shapes

Multiple geometric scanning options for the fractional head.

12.1-Inch Touchscreen

A large digital operating interface with dedicated function menus.

Six-Joint Articulated Arm

A flexible optical delivery configuration.

Multiple Applicator Designs

Fractional, ultra-pulse, and specialized accessory options.

Internal Cooling

A manufacturer-described circulation system for equipment cooling.

Frequently Asked Questions

What is the BG862 fractional CO2 laser machine?

It is a professional 10600nm laser system with fractional scanning, multiple laser pulse modes, an articulated optical arm, and a 12.1-inch touchscreen.

What is the maximum listed laser power?

The manufacturer specifies an adjustable output range of 1–60W.

What is the difference between 60W and 450VA?

The 60W figure is the manufacturer's laser-output specification. The 450VA figure refers to apparent electrical input power.

How many fractional scan shapes are available?

Seven: point, line, rectangle, triangle, hexagon, square, and round.

Does the machine include an Ultra Pulse head?

An Ultra Pulse head is illustrated in the manufacturer's accessory configuration. Its inclusion in the final commercial package should be confirmed.

What screen size does the machine use?

A 12.1-inch capacitive touchscreen.

Does it include an articulated laser arm?

Yes. The supplier describes a six-joint articulated beam-delivery arm.

Does it have specialized gynecological applicators?

The brochure illustrates several specialized gynecological accessory designs. The exact included set and permitted applications require verification.

What is the aiming-beam wavelength?

The manufacturer lists a 650nm red diode aiming laser.

Does the machine have an internal cooling system?

Yes. The product materials describe internal circulating cooling and show water-related rear connections.

Can this equipment guarantee scar removal or skin tightening?

No. Specific outcomes depend on the exact device, procedural conditions, and supporting evidence.

What electrical supply does the BG862 require?

The supplied technical sheet does not identify a specific voltage range. Electrical compatibility must be confirmed for the final production version.

Request Professional Equipment Information

Explore the Cstruebeauty BG862 60W Fractional CO2 Laser Machine, featuring seven scanning patterns, a 12.1-inch touchscreen, multiple laser-output modes, and a six-joint articulated laser delivery arm.

Contact Cstruebeauty to request:

  • Complete optical specifications

  • Verified laser output and pulse characteristics

  • Final applicator and accessory list

  • Electrical supply requirements

  • Cooling and maintenance documentation

  • Specialized accessory cleaning and sterilization instructions

  • Professional wholesale quotation

  • International shipping information

Contact Cstruebeauty for detailed equipment specifications and B2B pricing.

Important Safety Information

CO2 laser equipment presents significant optical, thermal, electrical, and procedural hazards, including serious burns, eye injury, tissue damage, infection, and scarring.

This type of equipment requires qualified personnel, appropriate protective eyewear, controlled operating conditions, suitable laser safety procedures, and validated instructions.

Specialized intracavitary accessories require additional procedural training, cleaning or sterilization validation, and appropriate professional oversight.

No claim is made that this equipment is painless, completely risk-free, or guaranteed to produce a particular cosmetic or therapeutic outcome.

View full details